PERMEATION
Permeation (or breakthrough) is the process by which a chemical moves through a material at the molecular level. The physical test for this is described in International Standards (e.g., EN 16523), but is essentially a permeation cell consisting of two compartments, separated by the test specimen. The specimen’s outer surface is in contact with the challenge chemical, whereas the specimen’s inner surface is in contact with a collecting medium. The breakthrough time is deemed to have occurred when the permeation rate of the challenge chemical reaches the normalised permeation rate (for EN 16523, this is 1μg/min/cm²). The time taken for this to occur is then reported in minutes. Once breakthrough occurs, a glove is no longer providing adequate protection.
ASTM F739 is similar but the rate is defined as 0.1μg/min/cm². Therefore, with a lower rate, gloves tested against this US Standard with the same chemical/same % are likely to feature a shorter breakthrough period.
Breakthrough times will vary depending on the thickness of the gloves, the glove material, the concentration and volume of the chemical, the temperature, and whether the glove has been stretched or damaged in any way. These factors should be taken into consideration when carrying out risk assessments and updated regularly following information from manufacturers and safety alerts.
PENETRATION
Chemicals can penetrate through holes and other defects in the glove material. For a glove to be approved as a chemical protection glove, the glove shall not leak water or air when tested according to penetration.
International Standards (e.g., EN 374 give more information on this. All aspects of the test including the equipment must be assessed to avoid sharp edges damaging glove material.
DEGRADATION
Degradation is the change in the physical characteristics of a glove caused by contact with a chemical. Degradation may appear as flaking, swelling, disintegration, embrittlement, colour change, dimensional change, appearance, hardening and/or softening. Degradation shall be determined according to International Standard (e.g., EN 374) for each chemical. The degradation result, in percentage (%), should be available in the glove supplier’s literature.
GLOVE RANGE
Several glove types may be required if using more than one chemical, therefore thorough risk assessments must be carried out, referring to manufacturers’ information, and include all aspects of chemical use, volumes and concentrations. Training in glove use and selection will also help prevent chemical contact.
PPE and glove selection are part of the LabSAFE course we run at Oleochem NuLab Training. We can carry out training on site, or at our new specialised training centre in Bridge of Don.